WinRunner End-of-support and Migration Webinar

Make sure your HP emails always go straight to your inbox. Add sw-bulletins@info.hp.com to your address book! Need Help?
WinRunner End-of-Support Announcement
HP WinRunner Migration Webinar: A Case Study from Travelocity» Register NowLive date: Tuesday, March 11, 2008 Start time: 7:00 AM PT9:00 AM CT10:00 AM ET3:00 PM GMTSpeakers: Rachel Pilgrim, QA Manager,TravelocitySatish Atluri, HP QM Global Practices Roi Carmel, Functional Testing Product Manager, HP Software

Learn more

» WinRunner End-of-Support Announcement» WinRunner migration data sheet
Find out how to accelerate migration from WinRunner to QuickTest Professional »

IMPORTANT ANNOUNCEMENT FOR WINRUNNER USERSHP Software is announcing end-of-support for HP WinRunner software, all versions (7.5, 7.6, 8.0, 8.2, 9.2). This end-of-support is based on our decision to consolidate and focus our functional testing offerings (HP WinRunner and HP QuickTest Professional) to maximize value to our customers. For migration options, support end dates and a list of FAQs, read the entire announcement here.Migration WebinarTo assist you with the migration from HP WinRunner to HP QuickTest Professional, we are hosting a Webinar with HP Professional Services (PS) and Travelocity who pioneered the HP WinRunner to HP QuickTest Professional migration effort. In this Webinar, Travelocity will share how they leveraged Gallop Technologies’ WinQuick – an HP R&D validated and approved automated migration solution – to automatically migrate and re-architect their HP WinRunner code base to HP QuickTest Professional. You will learn:
• What options Travelocity evaluated before undertaking this migration
• How Travelocity was able to perform this migration within budget and in less time than expected while at the same time increasing adoption of HP QuickTest Professional across the enterprise
• How you can replicate Travelocity’s success in your own organization
Don’t miss this opportunity to get insights from a customer who had great success with this migration.

Technology for better business outcomes
» HP Software
» Sales
» Privacy Policy
» Unsubscribe

If you received this e-mail from a friend and/or would like to subscribe to our e-mail list to receive future promotions and special offers, please click here.HP respects your privacy. If you'd like to discontinue receiving e-mails from HP regarding special offers and information, please click here.For more information regarding HP's privacy policy or to obtain contact information please visit our privacy statement or write to us at: Privacy Mailbox, 20555 SH 249, Houston, Texas 77070, ATTN: HP Privacy MailboxHewlett-Packard websiteSign-up for Driver and Support Alerts

Verify Broken Links using VBscript (without checkpoints)

One of my friends just wanted to check for the broken links (both textlinks and image links) on the page with VB script and not the checkpoints.
So the answer for that was the following code
---------------------------------------------------------
set
obj=Browser("name:=Blackboard.*").Page("title:=Blackboard.*").Frame("name:=main.*").object.all.tags("IMG")

msgbox obj.length

For each element in obj
s1=element.nameProp

If Browser().Page().Frame().Image("file
name:="&s1,"index:=0").exist(0) then
If Browser().Page().Frame().Image("file
name:="&s1,"index:=0").Object.complete="True" then

msgbox "pass"

else
msgbox "fail"

end if
end if

Next
---------------------------------------------------------

Code provided by my friend Shiva

Multiple Exit ways

It’s very easy to control the entry gate to an action or function - there’s only one way to enter them. However, the number of exit gates can vary widely from 1 to many according to the inner logic of the action/function. Today I’m going to address managing multiple exit gates in actions and functions.
When everything goes according to plan, an action flow tends to be very simple. There may be inner loops, If or Select switches, but for the most part, the flow just runs straight down to the last line. The problems usually appear when… well, problems appear. If an application error occurs, or even just an unexpected business logic behavior, there might be no escape from immediately exiting the action. There’s no point trying to input 20 data fields, if the form they’re in didn’t even open, is there?
Thankfully, the nice guys and gals at Mercury have taken this into account, and have provided us with the ExitAction and ExitActionIteration commands. So usually we’ve got something like the following:

‘.Action Code

If CritialCondition = False Then ExitAction

‘.Continue Action

But this is uninformative. So we add a reporter command:

If CritialCondition = False Then

Reporter.ReportEvent MicFail, "Something terrible has happened", "Aborting"
ExitAction
End If
And we probably got some objects to remove from memory:

If CritialCondition = False Then

Reporter.ReportEvent MicFail, "Something terrible has happened", "Aborting"

oFile.Close

Set oFile = Nothing

ExitAction

End If
============================================

Ho wait, we’ve gathered some data we need to report back:

If CritialCondition = False Then

Reporter.ReportEvent MicFail, "Something terrible has happened", "Aborting"

oFile.Close

Set oFile = Nothing

DataTable("out_EntityID", dtlocalsheet) = sEntityID

‘More here

ExitAction

End If

========================
Well, you probably get the picture. Pretty soon we get massive amounts of code in all the exit gates. This means we have duplicate code to maintain. Duplicate code is the digital manifestation of pure evil – and it’s never a good idea to have pure evil in you actions. Seriously though, this is exactly the kind of things that produces untraceable bugs, and it must be avoided at all cost.
So, how can we deal with this situation? One way is to create an exit gate function. It’s the ONLY function I ever put within an action, and not in an external file. Here’s an example of my action template, with the function:

Dim sResult ‘I store result data and values to be reported up the

‘action-call chain

Dim sActionReport ‘Instead of flooding the log with inner-action messages,

‘I store them, and report all of them at the exit gate.

‘Errors are still reported on-the-fly

‘Action code goes here

‘All the exit gates execute only one command : ActionEnd.

‘It receives two parameters: Boolean for Pass/Fail,

’string for the exit reason

If CriticalCondition = False Then Call ActionEnd(False, "Reason for exiting")

‘Rest of action

‘Even the normal successful action exit is managed through ActionEnd,

’so the last line in every action is:

Call ActionEnd(True, "Action successful")

Sub ActionEnd(bStatus, sReason)

‘Report details

Reporter.ReportEvent MicGeneral, "Inner Action Logs", sActionReport

If bStatus = True Then

Reporter.ReportEvent MicFail, "An error has occurred", sReason

Else

Reporter.ReportEvent MicPass, "Action successful", "See inner logs"

End if

‘Plant datatable info for action-call chain

DataTable("out_Status", dtlocalsheet) = bStatus

DataTable("out_Result", dtlocalsheet) = sResult

‘More if needed

‘Close objects and set to nothing here

‘Other needed exit code

ExitActionIteration

End Sub

With this mechanism, maintaining the exit code becomes very simple, and the logs are much more readable. Ok, so this solves the problem for actions, but what about functions? Well, obviously we can write an inner function within a function, but there is an alternative solution. It’s less elegant than the ActionEnd solution by far, and is harder to maintain, so I recommend using it only in a small number of very complex functions.
The solution is based on the Execute command, so I recommend reading about it in QTP’s help file in case you’re not familiar with it. In a nutshell, the Execute command takes a string, and runs its contents as if it were VBScript code. So for instance the command Execute "msgbox(2)" will pop a message box with the number 2. Here’s an example for the solution, applied to the ComplexFunc function:

Function ComplexFunc

Dim sExitCode

Dim sResult

Dim oFile ‘will be FSO textstream

’separate code lines by vbcrlf or ":"

sExitCode = "oFile.Close" & vbcrlf & _

"Set oFile = Nothing" & vbcrlf & _

"ComplexFunc = sResult"

‘More exit code

‘Function code goes here

‘Exit Gate

If CriticalCondition = False then

sResult = "False, No Connection"

Execute sExitCode

Exit Function

End if

‘More function code

‘Successful exit

Execute sExitCode

End Function

Creating and Calling user define funtion

Test Conditons: Creating and Calling user define funtion

1. Crate small add function and make it compile module.

2. calling that function in other test (using user defined data values)


[ Pre Requesties : Nothing ]

1a. open win runner blank test and add this below data

public function add(in a, in b)
{
return a+b;
}


1b. Go to File menu --> Test Properties (Test Properties window will open)
in General Tab --> Test Type= Compile module and ok

1c.Save the test in some location (Ex c:/tt )

2a.Before writing code , you have to load the funtction in to your folder , globally available to all tests.

2b. Go to Tools menu --> General Options
--- Select Folder option in the left pan.
-- Search Path for called test below enter the path of compile module
(c:/tt) and press "+" button to add in to.

2c. Write down the bleow code in the new test

load("c:/tt");
l= create_input_dialog("Enter First value");
j=create_input_dialog("Enter Second Value");
k=add(l,j);
report_msg(k);
unload("c:/tt");


[ load( ) , unload ( ) - to lload and unload from the memory ]

[Same way You can use Winrunner TSL Script to User Defined function